Worcester boiler broken down? Get the Fault codes here

April 29, 2026

Worcester boiler flashing an error? We’ve compiled fault codes and recommended fixes for every Greenstar model โ€” Si Compact, CDi Classic, and the 25i / 30i / 32i range.

๐Ÿ”ฅ Worcester Greenstar i (25i / 30i / 32i)

5

  • EA โ€“ Ignition failure (no flame detected)
  • F7 โ€“ Flame detected before ignition
  • FA โ€“ Flame detected after shutdown
  • F1 โ€“ Low pressure / dry fire
  • E9 โ€“ Overheat thermostat triggered
  • E2 โ€“ Flow temperature sensor fault
  • E5 โ€“ Flow temperature too high
  • A1 โ€“ Pump dry run / airlock
  • CE โ€“ Low system pressure
  • C6 โ€“ Fan speed fault
  • C7 โ€“ Fan not running
  • C1 โ€“ Fan interruption
  • C4 โ€“ Fan/control issue
  • D4 โ€“ Rapid temp rise
  • FD โ€“ Power interruption
  • F0 โ€“ PCB / gas valve fault
  • B1 โ€“ Code plug missing
  • B7 โ€“ Burner control fault
  • EF โ€“ Circulation fault
  • D3 โ€“ External limiter

Worcester Greenstar Si Compact

  • EA โ€“ Ignition failure
  • F7 โ€“ Flame before ignition
  • FA โ€“ Flame after shutdown
  • F1 โ€“ Low pressure / circulation issue
  • E9 โ€“ Overheat
  • E2 โ€“ Flow sensor fault
  • E5 โ€“ High flow temp
  • A1 โ€“ Pump issue
  • CE โ€“ Low pressure
  • C6 โ€“ Fan speed fault
  • C7 โ€“ Fan not running
  • C1 โ€“ Fan stops mid-cycle
  • C4 โ€“ Fan/control issue
  • D4 โ€“ Rapid temp rise
  • FD โ€“ Power interruption
  • F0 โ€“ PCB fault
  • B1 โ€“ Missing code plug
  • B7 โ€“ Burner control fault
  • EF โ€“ Circulation issue
  • D5 โ€“ Condensate issue

๐Ÿ”ฅ Worcester Greenstar CDi Classic

https://images.openai.com/static-rsc-4/u_ztkNtfBp7Wq3vuXP7zi24rqGkWIEum497QTeQMVj8dKGnuSp1xOX9dVrnDFCMTGB9AoOcrD9SOHrHhS12loQ8m2HThMB_UjmkQAQ6A7bP1e54SgkZ-k_1UFmi22s90B2MuzXwVgYQQCQg9KiKOjOJulcR9lgaLQKEq_ju31ytvlG4U2v52vQDthy9mIl_v?purpose=fullsize

  • EA โ€“ Ignition failure
  • F7 โ€“ Flame pre-ignition
  • FA โ€“ Flame post shutdown
  • F1 โ€“ Low pressure
  • E9 โ€“ Overheat
  • E2 โ€“ Flow sensor fault
  • E5 โ€“ Over temp
  • A1 โ€“ Pump dry run
  • CE โ€“ Low pressure
  • C6 โ€“ Fan fault
  • C7 โ€“ Fan failure
  • C1 โ€“ Fan interruption
  • C4 โ€“ Fan/control fault
  • D4 โ€“ Temp rise too fast
  • FD โ€“ Power fault
  • F0 โ€“ PCB fault
  • B1 โ€“ Code plug
  • B7 โ€“ Burner control
  • EF โ€“ Circulation fault
  • A7 โ€“ DHW sensor fault

๐Ÿ”ฅ Worcester Greenstar 2000

  • EA โ€“ Ignition failure
  • 227 โ€“ Flame loss during operation
  • F1 โ€“ Low pressure
  • E9 โ€“ Overheat
  • E2 โ€“ Sensor fault
  • E5 โ€“ High temp
  • A1 โ€“ Pump fault
  • CE โ€“ Low pressure
  • C6 โ€“ Fan speed fault
  • C7 โ€“ Fan failure
  • C1 โ€“ Fan stops
  • C4 โ€“ Fan/control issue
  • D4 โ€“ Rapid temp increase
  • FD โ€“ Power reset
  • F0 โ€“ Control fault
  • B1 โ€“ Code plug issue
  • B7 โ€“ Burner fault
  • EF โ€“ Circulation issue
  • D5 โ€“ Condensate fault
  • 9U โ€“ Control module fault

๐Ÿ”ฅ Worcester Greenstar 4000

https://images.openai.com/static-rsc-4/X9tFCxOM_opSUDg5hFlCGZoLidpYeBm4Uct5BGYH25aeYT5igg-vsjEAG3CGjwZ7LwVTfYcPBsDmE90RKkbXqg-N4IscQIaL4GlRuyDi4izVO3a3756HBcDSyNxTYy5VknAMpURjhiWbv5FLiRMG0t3yn0autkuDCZtqpT5p103rcBYl1XTXhiNPNv4xNa0Y?purpose=fullsize

7

  • EA โ€“ Ignition failure
  • 227 โ€“ Flame loss
  • 228 โ€“ Flame detected incorrectly
  • E9 โ€“ Overheat
  • 219 โ€“ Safety thermostat
  • E2 โ€“ Flow sensor fault
  • E5 โ€“ High temp
  • A1 โ€“ Pump issue
  • CE โ€“ Low pressure
  • C6 โ€“ Fan fault
  • C7 โ€“ Fan not running
  • C1 โ€“ Fan interruption
  • C4 โ€“ Fan/control fault
  • D4 โ€“ Rapid temp rise
  • FD โ€“ Power issue
  • F0 โ€“ PCB fault
  • B7 โ€“ Burner control
  • EF โ€“ Circulation issue
  • D5 โ€“ Condensate fault
  • 9A โ€“ Control module mismatch

๐Ÿ”ฅ Worcester Greenstar 8000 (Style / Life)

  • EA โ€“ Ignition failure
  • 227 โ€“ Flame loss
  • 228 โ€“ False flame detection
  • 229 โ€“ Flame instability
  • E9 โ€“ Overheat
  • 219 โ€“ Safety stat triggered
  • E2 โ€“ Sensor fault
  • E5 โ€“ High temperature
  • A1 โ€“ Pump fault
  • CE โ€“ Low pressure
  • C6 โ€“ Fan speed fault
  • C7 โ€“ Fan not running
  • C1 โ€“ Fan interruption
  • C4 โ€“ Fan/control issue
  • D4 โ€“ Rapid temp rise
  • FD โ€“ Power interruption
  • F0 โ€“ PCB fault
  • B7 โ€“ Burner control fault
  • EF โ€“ Circulation fault
  • 9U โ€“ Internal module fault

ย